Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transl Vis Sci Technol ; 12(12): 21, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38149965

RESUMO

Purpose: The purpose of this study was to determine changes in spatial and depth vision with increasing severity of keratoconus and to model the structure-function relationship to identify distinct phases of loss in visual function with disease severity. Methods: Best-spectacle corrected, monocular high-contrast visual acuity, contrast sensitivity function (CSF) and stereoacuity of 155 cases (16-31 years) with mild to advanced bilateral keratoconus was determined using standard psychophysical tests. Disease severity was quantified using the multimetric D-index. The structure-function relationship was modeled using linear, positive exponential, negative exponential, and logistic nonlinear regression equations. Results: The logistic regression model explained the highest proportion of variance for spatial vision, without bias in the residual plots (R2 ≥ 66%, P < 0.001). Visual acuity showed a distinct ceiling phase and a steeper loss rate with increasing D-index (1.8 units/D-index) in this model. The area under the CSF lacked this ceiling phase and had a shallower loss rate (0.28 units/D-index). Stereoacuity loss with D-index was poorly explained by all models tested (P ≤ 0.2). Cases with lower and bilaterally symmetric D-index had better stereoacuity (181.6-376 arc seconds) than those with higher D-index (>400 arc second); both were significantly poorer than controls (approximately 30 arc second). Conclusions: Vision loss in keratoconus varies with the visual function parameter tested. Contrast sensitivity may be an earlier indicator of spatial vision loss than visual acuity. Depth perception is significantly deteriorated from very early stages of the disease. Translational Relevance: The study outcomes may be used to forecast longitudinal vision loss in keratoconus and to apply appropriate interventions for timely preservation/enhancement of vulnerable visual functions.


Assuntos
Ceratocone , Humanos , Ceratocone/complicações , Ceratocone/diagnóstico , Acuidade Visual , Relação Estrutura-Atividade
2.
Vision Res ; 212: 108310, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37582329

RESUMO

Contrast detection thresholds are elevated with optical quality loss in keratoconus. This study hypothesized that suprathreshold contrast perception is also impaired in keratoconus, with the impairment being predictable from the pattern of loss in threshold-level performance. Contrast detection thresholds were determined across a range of spatial frequencies in 12 cases with mild to severe keratoconus and 12 age-similar controls. These values were used to predict the contrast needed to achieve perceptual matches between reference and test spatial frequency pairs (peak of CSF Vs. 0.3x, 0.5x, 2x or 3x spatial frequency from the peak) for stimuli at 10% and 50% suprathreshold contrast. Contrast thresholds predicted a 1.5 to 6.7-fold increase in the test pattern's contrast to obtain a perceptual match with the reference pattern in keratoconus, relative to controls. Contrary to predictions, the empirical data of contrast matches between test and reference patterns were similar for higher than peak spatial frequencies at both contrast levels. However, as predicted, test patterns required higher contrast than the reference pattern for a perceptual match for lower than peak spatial frequencies. These results were similar to controls and invariant of disease severity, interocular asymmetry and short-term changes in optical quality. Unlike thresholds, suprathreshold contrast perception of resolvable high spatial frequencies appears immune to optical quality losses in keratoconus. These results are discussed in the context of the prevailing models of contrast constancy in healthy humans. Breakdown of contrast constancy at lower than peak spatial frequencies may reflect the properties of the testing paradigm employed here.

3.
Cont Lens Anterior Eye ; 46(2): 101794, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36513565

RESUMO

PURPOSE: To determine 1) the relative differences in optical quality of keratoconic eyes fitted with four routinely used CL designs and 2) the Zernike coefficients in the residual wavefront aberration map that may be responsible for differences in the optical quality of keratoconic eyes fitted with these CLs. METHODS: Wavefront aberrations over a 3-mm pupil diameter were measured without and with Kerasoft IC®, Rose K2®, conventional spherical Rigid Gas Permeable (RGP), and Scleral CLs in 15 mild to moderate keratoconic eyes (20 - 28 years) and under unaided viewing in 10 age-similar non-contact lens wearing controls. The resultant through-focus curves constructed for the logarithm of Neural Sharpness (logNS) Image Quality (IQ) metric were quantified in terms of peak value, best focus, and depth of focus. Sensitivity analyses determined the impact of the residual Zernike coefficients of keratoconic eyes fitted with CLs on the IQ of controls at emmetropic refraction. RESULTS: The peak IQ and depth of focus were similar with Rose K2®, conventional RGP, and Scleral CLs (p > 0.05, for all) but significantly better than Kerasoft IC® CLs (p < 0.01 for all). Best focus was similar across all four CLs (p > 0.2 for all). However, the IQ parameters of all the lenses remained significantly poorer than the controls (p < 0.01, for all). The IQ of the controls dropped to keratoconic levels with induced residual lower-order Zernike terms and 3rd-order coma across all lenses in the sensitivity analysis (p < 0.001). CONCLUSIONS: IQ of keratoconic eyes remain suboptimal with routinely dispensed CL designs, largely due to residual lower-order aberrations and coma, all relative to the controls. The performance drop appears greater for the Kerasoft IC® CL relative to the other CL designs. These results may provide the optical basis for psychophysical spatial visual performance reported earlier across these four CL designs for keratoconus.


Assuntos
Lentes de Contato , Processamento de Imagem Assistida por Computador , Ceratocone , Retina , Adulto , Humanos , Adulto Jovem , Estudos de Casos e Controles , Desenho de Equipamento , Ceratocone/diagnóstico por imagem , Ceratocone/fisiopatologia , Ceratocone/terapia , Retina/diagnóstico por imagem , Retina/fisiologia , Resultado do Tratamento
4.
Optom Vis Sci ; 99(10): 763-773, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36067396

RESUMO

SIGNIFICANCE: Nonlinearity in the luminance profile of eccentric, infrared photorefraction may be used to differentiate corneal diseases such as keratoconus that distort the cornea, relative to regular refractive errors. PURPOSE: This study aimed to determine the profile of eccentric, infrared photorefraction in keratoconus as a prototypical disease model for distorted corneas and identify a parameter in this profile for differentiating such disease conditions from healthy controls. METHODS: Photorefraction reflex of 75 eyes with forme fruste to advanced keratoconic cases and that of 75 eyes of controls with regular refractive errors (spherical equivalent, +0.50 to -11.75 D; astigmatism, -0.50 to -4.50 D across 0 to 180° axes) were obtained over their natural pupils under unaided viewing using a custom-designed photorefractor placed at 1 m from the subject. The test was repeated in 10 controls with 4 and 6 D of trial-lens-induced myopia and myopic astigmatism at 0, 90, 45, and 135°. Linear regression was performed on the luminance profile across the pupil, and the departure of the data from linearity was estimated using the average residual error of the fit (Res avg ). RESULTS: Photorefraction profiles varied linearly across the pupil in controls, with slopes increasing with refractive error ( r = 0.87; P < .001) and Res avg remaining invariant of refractive error ( r = -0.29; P > .4). Corresponding profiles in keratoconus significantly departed from linearity, with Res avg progressively increasing with disease severity ( r = 0.66; P < .001). Res avg of 0.03 gray-scale units/pixel distinguished keratoconus from controls with sensitivity increasing from 66.7 to 100% for mild to advanced keratoconus and specificity remaining ≥97.1% across disease severity. Induced myopia and myopic astigmatism produced predictable changes in luminance profile slopes but with no change in Res avg values. CONCLUSIONS: Unlike regular myopia and astigmatism, the photorefraction reflex is significantly nonlinear in keratoconus because of the distorted cornea. Measures of nonlinearity in luminance profile may be incorporated in commercial photorefractors for differentiating such disease conditions from regular refractive errors.


Assuntos
Astigmatismo , Ceratocone , Miopia , Erros de Refração , Astigmatismo/diagnóstico , Córnea , Topografia da Córnea , Humanos , Ceratocone/diagnóstico , Refração Ocular
5.
Semin Ophthalmol ; 37(7-8): 869-886, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35786147

RESUMO

PURPOSE: Optical imperfections of the eye, characterized by higher-order wavefront aberrations, are exaggerated in corneal disease (e.g., keratoconus) and iatrogeny (e.g., keratorefractive surgery for myopia correction, keratoplasty for optical clarity restoration). This article reviews the recent advances on this topic for a comprehensive understanding of how optical degradations in disease models impact retinal image quality and monocular and binocular visual performance. METHODS: Published literature over the last decade on retinal image quality and/or monocular and binocular visual functions with corneal irregularity was reviewed based on their relevance to the current topic, study population and strength of study design. The literature was summarized into four themes: 1) wavefront errors and retinal image quality of highly aberrated eyes, 2) monocular and binocular vision loss consequent to degraded optics and visual strategies to optimize performance, 3) impact of optical correction modalities on visual performance and 4) implications for clinical management of patients. RESULTS: Across the 46 articles reviewed, the results clearly indicated that an increase in higher-order aberrations across these conditions had a significant negative impact on the patient's retinal image quality, and monocular and binocular visual functions. Interocular differences in retinal image quality deteriorated visual performance more than an overall worsening of image quality bilaterally. Minimizing optical degradation using rigid contact lenses and adaptive optics technology significantly improves retinal image quality and monocular and binocular vision, but performance remains sub-optimal relative to age-similar healthy controls. CONCLUSION: Corneal disease and iatrogeny are useful models to understand the impact of optical degradation on retinal image quality and visual performance. Clinical management will greatly benefit from equalizing retinal image quality of both eyes of these patients. Future studies that deepen our understanding of the structure-function relation in these conditions are desirable for advancing vision science in this area and for developing novel clinical management strategies.


Assuntos
Ceratocone , Visão Binocular , Humanos , Acuidade Visual , Visão Ocular , Óptica e Fotônica , Transtornos da Visão , Visão Monocular
6.
F1000Res ; 11: 6, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35136587

RESUMO

Background: While scleral lens practise has improved over the years due to factors such as availability of lenses with better materials and designs as well as experience of practitioners, a lack of objectivity appears to remain in terms of assessment of scleral lens fitting. This prospective observational work aimed to achieve standardization on this front through proposing a grading system for scleral lens fitting. Methods: After application of prosthetic replacement of ocular surface ecosystem (PROSE) devices on the participants' eyes, four fundamental components for understanding scleral lens fitting such as central and limbal corneal clearance, mid-haptic compression, and alignment of lens edge over anterior sclera were assessed through a series of slit-lamp biomicroscopy imaging as well as with anterior segment optical coherence tomography. FitConnect® was used to modify the device parameters to simulate different grading patterns on the proposed scale. Serial imaging was done for all the different lenses to compose the grading scale. Results: A clinically relevant grading scale was constructed that pictorially demonstrated grades for the different aspect of scleral lens fitting. The grades were conveniently scaled within three categories: "optimal", "acceptable" and "not acceptable". Conclusion: The gradation of scleral lens fitting parameters would take a step towards objectifying the assessment patterns in practise. This will also help reducing the gap between a novice and an experienced practitioner in terms of understanding of scleral lens fitting.


Assuntos
Lentes de Contato , Ecossistema , Humanos , Ajuste de Prótese/métodos , Esclera , Tomografia de Coerência Óptica/métodos
7.
Sci Rep ; 12(1): 403, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013498

RESUMO

This paper presents a twelve-port ultra-wideband multiple-input-multiple-output (MIMO)/diversity antenna integrated with GSM and Bluetooth bands. The twelve-port antenna is constructed by arranging four elements in the horizontal plane and eight elements in the vertical plane. The antenna element, which is created using a simple rectangular monopole, exhibits a frequency range of 3.1 to 12 GHz. The additional Bluetooth and GSM bands are achieved by introducing stubs into the ground plane. The size of the MIMO antenna is 100 × 100 mm2. The antenna offers polarization diversity, with vertical and horizontal polarization in each plane. The diversity antenna has a bandwidth of 1.7-1.9 GHz, 2.35-2.55 GHz, and 3-12 GHz, the radiation efficiency of 90%, and peak gain of 2.19 dBi. The proposed antenna offers an envelope correlation coefficient of < 0.12, apparent diversity gain of > 9.9 dB, effective diversity gain of > 8.9 dB, mean effective gain of < 1 dB, and channel capacity loss of < 0.35 bits/s/Hz. Also, the MIMO antenna is tested for housing effects in order to determine its suitability for automotive applications.

8.
Clin Exp Optom ; 105(7): 761-770, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34538199

RESUMO

CLINICAL RELEVANCE: The peripheral refraction profile in myopes with different corrective modalities varies significantly for both distance and near viewing and will have implications in managing myopia. BACKGROUND: This study investigated how the magnitude of peripheral myopic defocus induced by Ortho-K varies with and without accommodation, and how this compares to single vision spectacles and soft-contact-lenses (SCL). METHODS: Relative peripheral refraction (RPR) of 18 young adults (spherical equivalent -1.00 D to -4.50 D) was determined along the horizontal meridian (±10°, ±20°, ±25°) during distance (3-metres) and near viewing (0.2-metres), and along vertical meridian (±10°, ±15°) for distance viewing alone. Measurements were obtained in an uncorrected state and with single vision spectacles, soft contact lens and Ortho-K. Changes in RPR and astigmatic components were compared between distance and near viewing with all different modalities. RESULTS: A significant interaction (p = 0.02) between relative peripheral refraction and the target distance (distance and near viewing) was found among different refractive modalities. Single overnight Ortho-K lens wear alone led to relative peripheral myopia for both distance (mean RPR ± SE: -0.92 ± 0.21D and -1.04 ± 0.22D) and near viewing (-0.71 ± 0.17D and -0.76 ± 0.20D). Comparisons of relative peripheral refraction between different corrective modalities at each eccentricity indicated statistical significance of RPR at extreme locations along both temporal and nasal meridian (±20 and ±25°, p < 0.05). RPR with soft contact lenses and spectacles were similar for both distance and near viewing (p > 0.05). CONCLUSION: Single overnight Ortho-K lens wear alone shifted the RPR in the myopic direction for both distance and near viewing in comparison with single vision spectacles and soft contact lenses. The Ortho-K lens designs that offer a large amount of mid-peripheral corneal steeping, in-turn leading to high relative peripheral myopia for both distance and near viewing and might offer beneficial effects on myopia control.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Óculos , Humanos , Miopia/terapia , Refração Ocular , Testes Visuais , Adulto Jovem
9.
Case Rep Ophthalmol ; 12(2): 501-506, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34248582

RESUMO

Post-surgical or traumatic corectopia is among the rare causes of monocular diplopia. A 26-years-old student presented to the Institute with a complaint of monocular double vision in the left eye. He had a penetrating ocular injury in the left eye and subsequently, undergone for multiple ocular surgeries. Following the final intraocular lens implantation, he experienced a monocular double vision in his left eye. Upon contact lens clinic presentation, visual acuities were 20/20 in the right and 20/320 in the left eye (improved to 20/25 with pinhole). Slit-lamp examination on the left eye revealed scarring in the superior nasal quadrant of the cornea, irregular mid-dilated pupil with exposed aphakic and pseudophakic portions. A range of different optical management options were implemented to eliminate monocular diplopia and to correct refractive error. Finally, a combination of prosthetic soft contact lens and spectacle correction was able to remove diplopia and provide binocular single vision.

10.
Indian J Ophthalmol ; 68(12): 2911-2917, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33229669

RESUMO

PURPOSE: To estimate the time taken for topometric indices to stabilize in keratoconic corneas following cessation of habitual RGP contact lens wear. METHODS: A total of 29 eyes of 20 patients, diagnosed with mild to severe keratoconus were included in this prospective observational study. All patients were experienced RGP contact lens wearers (either conventional RGP or Rose K2 lens) with each patient having used these lenses for at least a year. Corneal topography was performed immediately following discontinuation of habitual contact lens wear at baseline and each of four consecutive visits, 1-week apart. RESULTS: An overall reduction in the keratometry and thickness values were noted on tomography immediately following cessation of contact lens wear and these indices increased significantly in the 1st week (P < 0.001). Consecutive visits following the first visit did not show any significant change in the topometric parameters (P > 0.05). Subgroup analysis revealed a similar trend in eyes with "severe" keratoconus and in eyes fitted with the "three-point touch" philosophy. However, eyes with "mild-moderate" keratoconus and those fitted with "apical clearance" fitting philosophy showed marginal differences even within the 1-week period of lens cessation. CONCLUSION: Maximum changes in keratometry and pachymetry values following discontinuation of RGP lens wear stabilize within the 1st week of cessation of rigid lens wear in a keratoconic cornea. These changes were more pronounced in patients with severe keratoconus and those with an apical bearing fit. This information would be useful for practitioners to assess the progression of keratoconus in RGP lens users before collagen cross-linking.


Assuntos
Lentes de Contato , Ceratocone , Córnea , Topografia da Córnea , Humanos , Ceratocone/diagnóstico , Ceratocone/terapia , Ajuste de Prótese
11.
Cont Lens Anterior Eye ; 43(6): 568-576, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32238301

RESUMO

PURPOSE: While several advanced contact lens (CL) designs are commercially available for vision correction in keratoconus, their visual performance and optical quality, relative to each other and controls remains unclear. This prospective, crossover study tested the hypothesis that these CL designs would have a differential impact on visual performance and optical quality in subjects with advanced keratoconus, but not in early to moderate disease states. METHODS: Spatial vision (logMAR acuity and contrast sensitivity), depth vision (stereoacuity) and optical quality (higher-order wavefront aberrations) were measured on 28 bilaterally mild to advanced keratoconics (age: 20-28yrs; 15 males), novice to CL wear, and in 10 age-matched controls using well-established psychophysical and aberrometry techniques. All data were collected on keratoconic subjects with their spectacles and with conventional RGP, Kerasoft®, Rose K2® and Scleral RGP® CL's in randomized order, atleast a week apart from each other. RESULTS: All outcome variables deteriorated with keratoconus severity and improved with CL wear, relative to spectacles (p < 0.05). This improvement was smaller for Kerasoft CL (p < 0.05) and higher but comparable for the other three CL designs (p = 0.3), across all disease severity. Visual functions and optical quality outcomes never reached control levels for any correction modality (p < 0.05). CONCLUSION: Visual performance and optical quality in keratoconus does not appear to improve commensurately with the sophistication of CL design across disease severity. Non-visual factors like quality of CL fit, wearing comfort and cost may therefore drive the choice of CL dispensed in keratoconus more than the performance efficacy of these lenses.


Assuntos
Lentes de Contato , Ceratocone , Aberrometria , Adulto , Estudos Cross-Over , Humanos , Ceratocone/diagnóstico , Ceratocone/terapia , Masculino , Estudos Prospectivos , Adulto Jovem
12.
Eur J Pediatr ; 178(12): 1825-1832, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31588974

RESUMO

The current version of Neonatal Resuscitation Program no longer favors routine endotracheal suctioning (ETS) in non-vigorous newborns with meconium-stained amniotic fluid (MSAF) due to possibility of procedure-related harms and questionable benefits. However, it calls for additional research on this procedure to provide a definitive answer. The present study was conducted to evaluate the role of ETS in non-vigorous neonates of ≥ 34 weeks' gestation born through MSAF on the incidence of meconium aspiration syndrome (MAS). In this open-label randomized controlled trial, 132 non-vigorous neonates with MSAF were randomized to receive ETS (n = 66) or no-ETS (n = 66) during delivery room resuscitation (DRR). Primary outcome variable was incidence of MAS. Secondary outcome variables were requirement of DRR, need of respiratory support, development of complications, duration of hospitalization, and mortality. Both the groups were comparable with respect to maternal and neonatal characteristics. Incidence of MAS was 21 (31.8%) and 15 (22.7%) cases in ETS and no-ETS groups, respectively (relative risk (RR), 1.400, 95% confidence interval (CI), 0.793-2.470). The two groups did not differ with regard to DRR, need for respiratory support, and development of complications. Nine (13.6%) neonates in ETS group, and 5 (7.5%) in no-ETS group died (p > 0.05). Median (interquartile range) duration of hospital stay was 54 (31-141) h and 44 (26-102) h in ETS and no-ETS groups, respectively (p > 0.05).Conclusions: Routine ETS at birth is not useful in preventing MAS in non-vigorous neonates of ≥ 34 weeks' gestation born through MSAF.Trial registration: Clinical Trials Registry of India (CTRI/2015/04/008819).What is Known:• Routine endotracheal suctioning is of questionable benefit in non-vigorous newborns with meconium stained amniotic fluid and may have a possibility of procedure-related harms.What is New:• Routine endotracheal suctioning at birth is not useful in preventing meconium aspiration syndrome in non-vigorous newborns of ≥ 34 weeks' gestation born through meconium stained amniotic fluid.


Assuntos
Intubação Intratraqueal , Síndrome de Aspiração de Mecônio/prevenção & controle , Sucção/métodos , Feminino , Idade Gestacional , Humanos , Índia , Recém-Nascido , Tempo de Internação/estatística & dados numéricos , Masculino , Síndrome de Aspiração de Mecônio/complicações , Síndrome de Aspiração de Mecônio/mortalidade
13.
Cont Lens Anterior Eye ; 42(5): 526-532, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31146970

RESUMO

PURPOSE: To describe patterns of prescribing Prosthetic Replacement of Ocular Surface Ecosystem (PROSE) in irregular corneas and compare various components of lens design. METHODS: Design: Retrospective, observational case series. 244 eyes of 173 patients with keratoconus (n=178), pellucid marginal degeneration (n=21), keratoglobus (n=6), following refractive surgery (n=19) and following keratoplasty (n=20) fitted with the PROSE device were retrospectively analyzed. Simulated keratometry value along the steep meridian (Steep-K) and anterior chamber depth (ACD) were measured using Scheimpflug imaging. Improvement in visual acuity and parameters of lens design such as vault, front surface eccentricity (FSE) and toricity were analyzed and compared across all conditions. RESULTS: PROSE improved visual acuity, both uncorrected (median, 1.30 logMAR) and spectacle-corrected (median, 0.60 logMAR), to a median of 0.22 logMAR. Positive correlation was observed between Steep-K and ACD with lens vault, especially in keratoconus. Multiple regression analysis established ACD as the most reliable factor while choosing vault. FSE value of 0.6 was the most common across diagnostic subgroups. The distribution of FSE values did not differ between keratoconus patients with Steep keratometry of <60D or those >60D. In every diagnostic subgroup, at least 20% of eyes required a lens design of with-the-rule toricity of haptic. CONCLUSION: The PROSE device resulted in significant improvement in vision in this population. A trend of prescribing higher lens vault with increased keratometry value was evident especially in keratoconus. ACD appeared to be more important than Steep K in vault selection. An FSE of 0.6 and vertical peripheral lens toricity were used most frequently in this subset of patients.


Assuntos
Lentes de Contato Hidrofílicas , Córnea/fisiologia , Doenças da Córnea/terapia , Ecossistema , Acuidade Visual/fisiologia , Adulto , Doenças da Córnea/fisiopatologia , Topografia da Córnea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prescrições , Ajuste de Prótese , Estudos Retrospectivos , Adulto Jovem
14.
Cont Lens Anterior Eye ; 42(2): 226-228, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30337141

RESUMO

BACKGROUND: Nanophthalmos is rare developmental ocular condition characterized by a small eye with short axial length, high hyperopia and high lens to eye volume ratio due to arrested development of eye ball as a result of scleral inelasticity. OBSERVATIONS: A 33 year old woman who presented with a complaint of blurring of distance and near vision in both eyes since childhood came to LV Prasad Eye Institute on July 2017. Best corrected visual acuity was 20/60 using soft contact lens +23.50 diopters for the right and left eyes. Axial lengths of two eyes were markedly shortened along with steep corneal curvatures. Visante anterior segment ocular coherence tomography showed a steep (convex) corneo-scleral junction (CSJ) which might be the reason for ill-fitting with conventionally estimated soft contact lens (SCL) parameters. Finally, selection of the customized hydrogel soft contact lens base curve close to flatter corneal curvature and small diameter showed characteristics of optimal lens fit. CONCLUSION: The corneo-scleral junction profile plays significant role in soft contact lens fitting. An eye with a profile of convex CSJ would require a lens with steeper curvature compared to conventional measurements. Cases of nanophthalmos would require observation of the profile with the help of optical coherence tomography in addition to measurement of corneal curvature prior to fitting soft contact lenses.


Assuntos
Lentes de Contato Hidrofílicas , Limbo da Córnea/fisiologia , Microftalmia/fisiopatologia , Transtornos da Visão/terapia , Adulto , Topografia da Córnea , Feminino , Humanos , Ajuste de Prótese , Tomografia de Coerência Óptica , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia
15.
J Pediatr Hematol Oncol ; 37(7): e419-20, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26334428

RESUMO

Enterococcus fecalis is a nosocomial, opportunistic pathogen, known to cause late-onset sepsis in preterm neonates and is notorious for its association with high mortality and resistance to commonly used antibiotics, such as penicillin, ampicillin, aminoglycosides, and vancomycin. Neonatal leukemoid reaction, defined as the white blood cell count ≥50×10/L or absolute neutrophil count >30×10/L, is a poor prognostic factor in chorioamnionitis. Occurrence of neonatal leukemoid reaction in E. fecalis-mediated sepsis is rare. We report development of leukemoid reaction in a preterm, extremely low-birth-weight neonate with early-onset sepsis caused by E. fecalis that was resistant to ampicillin and aminoglycosides.


Assuntos
Infecções por Bactérias Gram-Positivas/complicações , Reação Leucemoide/complicações , Sepse/complicações , Resistência Microbiana a Medicamentos , Enterococcus faecalis , Feminino , Humanos , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Recém-Nascido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...